Featured · ³He
Movable In-Core (MIC) Neutron Detectors for PWR

Movable In-Core (MIC) Neutron Detectors for PWR

Movable In-Core detectors used by PWR utilities to map thermal neutron flux in the water gap between fuel bundles.

Movable In-Core detectors used by PWR utilities to map thermal neutron flux in the water gap between fuel bundles.
Gas Fill
³He · 1.8 atm
Op Temp
−40 → 200°C
Rated
Reactor / Downhole

Introduced in 1968 for PWR utilities, our MIC detector maps thermal neutron flux in the water gap between adjacent fuel bundles. Precisely matched, machined, and bonded MIC components increase reliability by minimizing detector failure from installation and removal. Compatible with all equipment vendors. Available in right-handed or left-handed models and custom lengths.

Specifications

Detector type
Proportional counter, ³He fill
Active length
50 – 1,500 mm
Active diameter
15.9 – 50.8 mm
Gas fill
³He @ 1.8 atm (custom 0.5 – 4 atm)
Sensitivity
~7.0 cps/nv (per cm active)
Operating voltage
+1,200 to +1,600 VDC
Plateau slope
<3% per 100 V
Op temperature
−40 °C to +200 °C
Pressure rating
Atm (std) / 20,000 psi (DH)
Gamma rejection
>10⁶ cps/R/h gamma field
Connector
MHV / BNC / Reynolds 167-2754
Certifications
ATEX · IECEx · CSA · UL CL1 D1
Custom Build

Need a different geometry?

If your operating conditions sit outside our standard catalog configurations, our application engineering team will spec a detector to match. Most custom builds reuse proven sensor architectures with tailored mechanical envelopes, connectors, and fill parameters.