Featured · ³He
Wide Range Neutron Monitor (WRNM)

Wide Range Neutron Monitor (WRNM)

Combines functionality of Source Range Monitor (SRM) and Intermediate Range Monitor (IRM) detectors into one solution.

Combines functionality of Source Range Monitor (SRM) and Intermediate Range Monitor (IRM) detectors into one solution.
Gas Fill
³He · 1.8 atm
Op Temp
−40 → 200°C
Rated
Reactor / Downhole

Startup instrumentation sensors calibrated for optimal measurements from below source level to ~10% of rated reactor power. Wide Range Neutron Monitor (WRNM) combines functionality of SRM and IRM detectors into a single integrated solution.

Specifications

Detector type
Proportional counter, ³He fill
Active length
50 – 1,500 mm
Active diameter
15.9 – 50.8 mm
Gas fill
³He @ 1.8 atm (custom 0.5 – 4 atm)
Sensitivity
~7.0 cps/nv (per cm active)
Operating voltage
+1,200 to +1,600 VDC
Plateau slope
<3% per 100 V
Op temperature
−40 °C to +200 °C
Pressure rating
Atm (std) / 20,000 psi (DH)
Gamma rejection
>10⁶ cps/R/h gamma field
Connector
MHV / BNC / Reynolds 167-2754
Certifications
ATEX · IECEx · CSA · UL CL1 D1
Custom Build

Need a different geometry?

If your operating conditions sit outside our standard catalog configurations, our application engineering team will spec a detector to match. Most custom builds reuse proven sensor architectures with tailored mechanical envelopes, connectors, and fill parameters.