The light intensity can be too low on Frame 5 DLN1 turbines to detect with standard flame sensors. Reuter-Stokes engineered a new model of the Flame Tracker Dry 325 with increased gain that are more sensitive to smaller UV signals for our sister com…

Marcus Chen, PhD

Principal Application Engineer · Downhole
RS-N7 compensated neutron logging tool, prepared for downhole deployment in a Permian Basin operator's lab.

Every gas turbine exhaust produces NOx emissions, the amount of which depends on combustion temperature. With a stochiometric fuel-to-air ratio (when the amount of air is precisely enough to consume all of the fuel in a combustion reaction), a large amount of NOx is produced. A turbine with dry low NOx combustion (DLN1), however, uses a fuel-lean ratio to minimize NOx. That requires precise premixing of fuel and air before ignition.
 

Each turbine has 10 combustion chambers, each having a plane of primary nozzles that are lit first for start-up, and a central secondary nozzle that’s lit next. Four of the chambers are equipped with flame sensors—one for the primary nozzles, and one for the secondary nozzle. So each turbine has eight flame sensors in all.

During start-up, the DLN1 system runs through multiple modes to get to premix mode. The transition to premix mode requires stopping fuel supply to the primary nozzles so those flames extinguish while the secondary flame continues burning. When the primary fuel is restarted, the fuel and air are premixed for combustion at the secondary nozzle.

For most gas turbine installations, a standard sensor like the Reuter-Stokes Flame Tracker Dry 325 (FTD 325) is used to help control this complex process. It’s a robust device with a hot-end assembly that operates at an impressive temperature of 325°C. Because of this, it requires no water or air cooling, which mitigates risks of compressor blade rubs caused by water leaks, and eliminates troublesome sensor failures due to inadequate cooling. The sensor is also easy to remove and reinstall during outages, so it saves the customer labor costs.

The FTD 325 senses ultraviolet (UV) wavelengths to signal if a flame is burning or not. The challenge with DLN1 turbines, however, is that light intensity can be too low for detection by standard sensors, as was the case recently at a customer’s LNG plant. When the two turbines were at transition to premix, very low levels of light reached their secondary sensors, even though the secondary flames were lit. So the turbines could not transition to premix mode—NOx emissions remained high, and the turbines couldn’t successfully complete the start-up process.

Solution

Our Reuter-Stokes team created a new version of the FTD 325, increasing the sensor’s gain so it can react to smaller UV signals like those occurring during the transition to-premix mode. They ensured that this change didn’t affect its sensitivity to bright light—so the new model has the same high reliability for baseload operation as the standard FTD 325 detectors.

As a test, two of the new FTD 325 ILG (increased low gain) sensors were installed at secondary flame locations in each of these Frame 5 DLN1 gas turbines. The customer was able to easily transition from lean-lean to premix combustion without interruption—enabling successful start-up of both units.

Benefits

With output levels twice as high as the standard sensors, the new ILG sensors performed as expected, and are an ideal fit for this application. Customers currently using the non-ILG version can easily upgrade if required by their turbine conditions. The new product’s success also gives customers yet another option, especially to replace older Geiger Muller-type sensors. The new sensor will work on any turbine model, not only DLN1, with no adverse effect or invalidation of specifications.

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Vestibulum eget orci ullamcorper, euismod justo quis, ultrices mi. Donec accumsan sapien eu magna facilisis tempus. Nam varius sollicitudin justo non aliquet. Aenean aliquet lacus massa, eu consequat nunc gravida et. Proin ac elit vel ipsum posuere aliquam. Cras in tellus vitae leo molestie tristique.

What actually drives downhole detector response.

In hac habitasse platea dictumst. Nunc ultrices in erat sit amet dictum. Cras odio sapien, gravida a elementum id, placerat eget magna. Vestibulum consectetur metus eu elit pulvinar porttitor. Quisque vitae elit ligula. Sed eu rhoncus ipsum. Praesent tempus ultrices metus lacinia malesuada.

The detector parameters that actually matter for compensated logging response, in order of magnitude of impact:

The pressure-length tradeoff in practice.

Curabitur porttitor enim nunc, in imperdiet est venenatis id. Nunc molestie sapien sed leo aliquam, nec bibendum nibh dignissim. Cras eu felis vel mauris pretium volutpat. Nulla ultricies sapien at sapien venenatis lobortis. Mauris vel elementum tortor.

Sensitivity-vs-length curves for ³He at 1.0, 1.8, 2.5 and 4.0 atm — measured response from RS-P4 production data, normalized at L=300 mm.

Fusce vel viverra arcu, tempor sagittis leo. Sed ut massa tincidunt, sodales ipsum eu, rhoncus erat. Integer et nunc fermentum, commodo sapien tincidunt, rhoncus massa. Praesent scelerisque non lacus non condimentum. Nullam id dignissim augue.

“

Doubling the gas pressure delivers more sensitivity than doubling the active length — and ships in a smaller, more rugged package.

— Marcus Chen, RS Application Engineering

Sed vitae facilisis nisl. Cras sed dui aliquam, faucibus lacus eget, bibendum ex. Nullam congue justo eu ullamcorper vulputate. Curabitur vitae ligula aliquam, venenatis turpis quis, pellentesque diam. Proin faucibus ultrices vulputate.

Practical guidance for replacement spec.

When spec’ing a replacement detector for a fielded compensated neutron logging string, work the problem in this order:

Integer a volutpat massa, et pulvinar quam. Cras dolor nunc, hendrerit quis mattis eu, placerat a quam. Aenean auctor hendrerit pharetra. Pellentesque eu urna mauris. Donec eu justo sit amet eros porta ullamcorper quis eu est. Phasellus nec volutpat tellus.

More news & events

Blog

Proportional Counters for Radiation Measurement: Principles & Applications

Proportional counters are designed for the detection and measurement of ionizing radiation. They generate an electrical signal that is directly proportional to the energy deposited by the incident radiation, allowing for detection AND the characteri…
READ MORE →
Blog

Simple, Reliable Flame Monitoring – It’s Common Sense

The Reuter-Stokes approach to flame sensing originated in the core of nuclear reactors. Known for precision radiation measurements in harsh environments, the design practices that were learned in the reactor are used to sense flame presence in gas t…
READ MORE →
Blog

The Role of Flame Sensors in Gas Turbines

Infrared flame sensors are popular for industrial burner applications like boilers or furnaces. They are also sometimes used on gas turbines – but there is a drawback to this approach.
READ MORE →
Blog

Paragon x Reuter-Stokes: The New Era of Nuclear

The Paragon and Reuter-Stokes Gamma Metrics Neutron Flux Monitoring Systems (NFMS) strategic collaboration ensures continued reliability, effectively safeguarding a critical component of nuclear safety while addressing challenges such as technologic…
READ MORE →